제목(국문) | 스크린메쉬형 VCHP에서 NCG량에 따른 열전달 성능실험 |
---|---|
제목(영문) | Influence of NCG Charged Mass on the Thermal Performane of VCHP with Screen Mesh Wick |
저자 |
박영실
(Young-Sik Park
,한국폴리텍IV 아산대학
)
▷공저자네트워크등록하기
정경택 (Kyung-Taek Chung ,경상대학교 BK21사업단 ) ▷공저자네트워크등록하기 서정세 (Jeong-Se Suh ,경상대학교 ) ▷공저자 네트워크 보기 |
초록 | Experimental study has been performed to investigate the influence of noncondensible gas(NCG) charged mass on the thermal performance of a variable conductance heat pipe(VCHP) with screen mesh wick. The VCHP is furnished by screen mesh number 200 for the pipe outer diameter of 12.7mm and the pipe length of 500 mm. The VCHP is filled with water as working fluid of 4.8 g and nitrogen as NCG and has evaporator, condenser and adiabatic section, respectively. For the results from experiment, it is found that, for the same charged mass of working fluid, the overall wall temperatures of heat pipe grows up with increasing NCG charged mass. The variation of operating temperature of VCHP reduces with increasing NCG mass. In addition, the profile of axial wall temperature distribution is presented for heat transport capacity of heat pipe, the temperature of cooling water of condenser, inclination angle, and operating temperature |
keyword | Mesh wick(메쉬 윅), Non-condensible gas(불응축 가스), Variable conductance heat pipe(가변전열 히트파이프), Working Fluid(작동유체) |
저널명 | 설비공학 논문집 ▷관련저널보기 |
VOL | 20 |
PAGE | 689-695 |
발표년도 | 2008 |
원문파일 |
![]() |